Classification:
Product Details
- 产品描述
-
- Commodity name: Column ultrafiltration membrane series membrane elements
The hollow fiber ultrafiltration membrane of Fumiao Membrane brand with independent intellectual property rights has excellent application effect in water treatment projects such as pure water preparation, tap water purification, water reuse, seawater desalination, brackish water treatment and etc. At present, it has been applied in many domestic projects for many years. At present, it has been used in many domestic projects for many years.
Product Characteristics
● PVDF material, chemical cleaning resistance, anti-oxidation performance is more excellent
● Average pore size 0.03μm, uniform pore size distribution
● Dual dense epidermal layers to ensure high precision filtration
● Double-layer casting process, effective protection of the root of the film wire
● Unique water flow channel structure, water distribution is more uniform, effectively control and reduce the concentration of polarization layer
Ultrafiltration process characteristics
● Operating at ambient temperature, the process is gentle with no phase change
● High-precision filtration, excellent water quality
● High water production rate per unit area, small system footprint
● High degree of system integration and easy expansion
● PLC full automatic control, safe and stable operation
Hollow Fiber Ultrafiltration Membrane Element Parameter List and Conditions of Use
Module Model FMU-P340 FMU-P660 FMU-P860 FMU-P960 FMU-P980 Effective membrane area(m²)
7
40
50
50
75
Water inlet and outlet
DN25
DN40
DN50
DN50
DN50
Overall dimensions(mm)
φ90×1148
φ160×1800
φ200×1884
φ225×1860
φ225×2360
Shell material
UPVC
Tip encapsulation material
环氧树脂/聚氨酯
Membrane material
聚偏氟乙烯(PVDF)
Membrane inner and outer diameter
0.7/1.3mm
Average pore size
0.03μm
Pure water flux
200L/(m² ·h)(25℃ 0.1MPa)
Turbidity of produced water
≤0.1 NTU
Water production SDI15
≤3.0
Operating Methods
External pressure
Operating mode
Constant voltage/current
Running mode
Full-volume filtering or staggered-flow filtering
Design Flux
30~60L/(m² ·h)(25℃ 0.1MPa)
Operating temperature
5-40℃
Maximum inlet pressure
0.3MPa
Maximum transmembrane pressure difference
0.15MPa
pH range
2-11(cleaning 1-12)
Maximum backwash water flow rate
150L/m² ·h
Backwash frequency
20~60minutes
Process Flow Diagram
Application areas
Water recycling and resource recovery
Industrial wastewater treatment
Groundwater treatment
Surface water treatment
Treatment and reuse of municipal sewage/drainage
Pre-treatment of reverse osmosis and nanofiltration membranes